9 Electrical CAM 9.2.3.2 Start / Stop Acyclic E-CAM In cyclic E-CAM, Master and Slave operate according to the user-defined E-CAM Data only when E-CAM start signal (START0/PG0) is triggered. Unlike cyclic E-CAM, acyclic E-CAM operates only one cycle for each triggered signal, i.e. E-CAM Data operates only once for one triggered signal. Before selecting START0 as the start signal, M1035 has to be set ON for setting STOP0/START0 as the external input. After M1035 is set OFF, M1746 = OFF will enable START0 as the start signal of acyclic E-CAM rather than PG0.

E-CAM Data Slave max =180 ( ) Slave unit Master =360 max ( ) Master unit „ Start Acyclic E-CAM The timing diagram below indicates an operation process of acyclic E-CAM operation with synchronized output position between 60~300. 1. In T1, D1846 bit 14 = ON, acyclic E-CAM is enabled 2. After the initialization interval of T2, M1812 = ON to indicate the completion of E-CAM initialization. At this time Slave is still not activated. 3. In T3, acyclic operation starts after START0/PG0 (Input terminal for enabling acyclic E-CAM) is ON. When M1746 = ON, PG0 is the start signal of acyclic E-CAM; when M1746 = OFF and M1035 = ON, START0 is the start signal of acyclic E-CAM.

In this case Slave starts to operate a cycle according to the E-CAM Data. (“M1035 = ON” enables START0 / STOP0 as the external input point). 4. When the cycle is completed at T4, DVP-PM will clear the state of M1812 = ON. In addition, users can 5. In T5, you can decide whether to set ON M1812 for confirming the next E-CAM completion. also confirm the E-CAM completion by ON state of M1813. 6. In T6 and T7, actions of T3~T4 will be repeated. Please note that the interval for enabling acyclic E-CAM should be longer than 5ms. 7. CLR0 outputs according to the upper/lower bound of sync output during each E-CAM cycle. DVP-PM Application Manual 9-13