DOP W advanced alarm functions (EN)

Оригинальное название: DOP W advanced alarm functions

Читать онлайн

Похожие инструкции

Текст документа

Ne ewsl ette r DOP-W Series The adva anced alarm m function i n DOP-W s series HMI a allows users s to display the alarm b by the settin ng of Active Following e address, S gs are the d Sort address detailed des scriptions of s and Filter address. f global ala rm setting a and function ns provided by Alarm History T Table. Global a larm setting g can be div vided into tw wo categorie es, which ar re continuou us alarm ad ddress (A) a and non-cont tinuous alar rm address (B). A: Check [Con ntinuous ala arm address s] 23/61 Numb er Name Descr iptions Continuous Alarm Address The default setting of this function is enabled.

Its address setting should be identical to the alarm address that is set before. Category This represents the category of alarm number, which is similar to grouping. The supporting range is between 1 and 255. Monitoring Address It can be used to display the alarm message set by users. Add ³%d1´ after the alarm content you entered and when the value of monitoring address is 10, the alarm information shown in Alarm History Table will be Alarm10.

Стр. 1

Ne ewsl ette r B: Not to che eck [Contin nuous alarm m address ] 24/61 Numb er Name Descr iptions Alarm Screen Display It has two types, automatic and manual. When it sets to Automatic: If the alarm is triggered, the alarm screen will immediately pop up. When it sets to Manual: The display of alarm screen is controlled by setting the Action address to 2. Numbe r Na me Descript ions Continuous Alarm Address Uncheck this selection and the Read address will be disabled. According to the alarm type (Bit or Word), each alarm address can be triggered individually. Category It represents the alarm category, which is similar to alarm group. The supported group range is between 1 and 255.

Type The type can be Bit or Word. Bit: Define the Bit address for triggering alarms Word: Define the Word address for triggering alarms Address The triggering method is determined by its type, Bit or Word. When the type is Bit, please enter the Bit address to trigger the alarm. When the type is Word, the alarm can be triggered according to the conditional statement. Conditional Descriptions = equal to > greater than = greater than or equal to C onditional Descriptions = equal to > greater than less than >= greater than or equal to less than or equal to

Стр. 2

Newsletter 25/61 Number Name Descriptions >, out of the range within the range Monitoring Address It is used to display alarm messages set by users. Add ³%d1´ after the alarm content you entered and when the value of monitoring address is 10, the alarm information shown in Alarm History Table will be Alarm10. Alarm Screen Display When it sets to Automatic: When the alarm is triggered, the alarm screen will immediately pop up. When it sets to Manual: The display of alarm screen is controlled by setting the Action address to 2.

Стр. 3

Ne ewsl ette r W We have two o pages in A Alarm Histor ry Table, De etails and D Details-2. De etails The acc cording to th e control ad ddress prov he set items vided in Deta s. ails page al llows users to arrange and select the alarm 26/61 No. Name Descript ions Action address Action address allows the specified alarm can be displayed and acknowledged. Value Descriptions 0 Default status. No action will be done. 1 Acknowledge the selected alarm in Alarm History Table. If the selected alarm has alarm screen and the screen display is 2 set to Manual, when the value is 2, it will display the alarm screen. Sort address The sort address will arrange and display the item specified by users.

Value Descriptions 0 Default status. No action will be done. 1 Arrange the item according to the Trigger Time 2 Arrange the item according to the Acknowledge Time 3 Arrange the item according to the Recovery Time 4 Arrange the item according to the alarm counts 5 Arrange the item according to the alarm type 6 Arrange the item according to the alarm number Value De scriptions 0 Default status. No action will be done. 1 Acknowledge the selected alarm in Alarm History Table. 2 If the selected alarm has alarm screen and the screen display is set to Manual, when the value is 2, it will display the alarm screen. Value De scriptions 0 Default status. No action will be done.

1 Arrange the item according to the Trigger Time 2 Arrange the item according to the Acknowledge Time 3 Arrange the item according to the Recovery Time 4 Arrange the item according to the alarm counts 5 Arrange the item according to the alarm type 6 Arrange the item according to the alarm number